3.05 Gouging Operation Settings

“Table 3-12: Operating Parameters”” shows recommended operating amperage by electrode sizes. The travel

speeds listed for each size carbon and gouge depth were derived in the laboratory using a 1500 amp Power Supply.

Your results may vary depending on the arc current, voltage and other parameters you use.

Automatic Gouging Operating Data

Electrode Diameter

Desired Depth

DC Current

Travel Speed Per Min.

Inch

mm

Inch

mm

Amps

Inch

mm

5/16

7.9

1/8

3.2

400

65

1651

5/16

7.9

3/16

4.8

400

45

1143

5/16

7.9

1/4

6.4

450

36

914

5/16

7.9

5/16

7.9

450

33

838

5/16

7.9

7/16

11.1

500

22.5

572

3/8

9.5

1/8

3.2

500

70

1778

3/8

9.5

3/16

4.8

500

44

1118

3/8

9.5

1/4

6.4

500

35

889

3/8

9.5

3/8

9.5

500

20

508

3/8

9.5

9/16

14.3

500

17.5

445

1/2

12.7

1/8

3.2

850

96

2438

1/2

12.7

1/4

6.4

850

57

1448

1/2

12.7

3/8

9.5

850

35

889

1/2

12.7

1/2

12.7

850

24

610

1/2

12.7

3/4

19.1

850

17.5

445

5/8

15.9

1/4

6.4

1250

72

1829

5/8

15.9

3/8

9.5

1250

48

1219

5/8

15.9

1/2

12.7

1250

37

940

5/8

15.9

5/8

15.9

1250

30

762

5/8

15.9

15/16

23.8

1250

19.5

495

3/4

19.1

1/4

6.4

1400

72

1829

3/4

19.1

3/8

9.5

1400

42

1068

3/4

19.1

1/2

12.7

1400

34

865

3/4

19.1

5/8

15.9

1400

27

687

3/4

19.1

3/4

19.1

1400

22

560

3/4

19.1

11/8

28.6

1400

13

330

Table 3-12: Operating Parameters

NOTE

If you want a groove depth that is greater than 1-1/2 times the diameter of the electrode being used,