04 control box installation, 04 control box installation -4, N7500 assembly and installation – Tweco N7500 User Manual

Page 30

Advertising
background image

N7500

ASSEMBLY AND INSTALLATION

ASSEMBLY AND INSTALLATION

4-4

Manual 89250890

4.04 Control Box Installation

Determine where the Control Box should be located in relationship to where the gouging will take place. It is not

recommended to carry the Control Box on any travel system other than the Victor Arcair Titan

®

Machine Carriage

due to the added weight of the Control Box and the weight of the power cables coming from the DC Power Supply.
The Control Box can be secured to a stationary surface with the mounting brackets on both sides. Refer to "Table

3-2: Control Box Features" on page 3-2 for the mounting brackets and "Figure 3-4: RIGHT Side of Control Box"

and "Figure 3-5: BACK of Control Box" on page 3-3 for bracket locations.

NOTE

DO NOT force connections. All connectors should be fastened easily. Be sure to tighten connections

as you go through each step. Avoid crimping hoses or wires.

WARNING

Select the receptacle voltage that correctly matches the plug and power requirements of the Carriage

System.

WARNING

Confirm that the Power Supply and Control Box Power In switches are OFF.

Make the following connections from Power Supply to Control Box and work piece. See "Figure 4-8: Assembly

Stage 1".

WORK PIECE

SIGNAL WIRE

GROUND CABLE (–)

CONTROL BOX INPUT

AC POWER CABLE

DC POWER CABLE (+) IN

INCOMING

AIR LINE

POWER

SUPPLY

CONTROL BOX

(VIEWED FROM CABINET LEFT SIDE)

ART# A-10850_AC

POWER SUPPLY

COMMUNICATION CABLE

AIR REGULATOR

GROUND CABLE (–

)

120V

OR

220V

MAX 100 psi

(Rear panel assembly

not shown for clarity)

Figure 4-8: Assembly Stage 1

1. Connect the air regulator to the side of the Control Box labeled “AIR IN”. Preset the regulator to the rec-

ommended operating pressure based on "Table 3-14: Compressed Air Input Requirements" on page 3-10.

(The compressed air inlet and outlet fittings on the Control Box are 1/2-14 NPT.)

2. Connect the incoming shop compressed air line to the air regulator. Charge the shop compressed air sup-

ply to the air regulator on the Control Box’s AIR IN side to confirm air pressure is within recommended

specifications. Refer to the specifications listed on the Control Box nameplate.

3. Attach the AC Power Cable to the connector labeled “POWER IN”.
4. Loosen the screws holding the Control Box rear cover plate. Re-position and tighten one screw.