Manual 89250890

5-5

SYSTEM OPERATION

SYSTEM OPERATION

N7500

ART# A-10824_AC

Menu Setting

Power Mode

CV

Parameter Guide

Current

850A

Figure 5-6: Parameter Guide Screen (using CV mode)

ART# A-10841_AB

Back

Unit

Inch

Diameter

Depth

3/8

9/16

ART# A-10842_AB

Back

Current

500A

Travel Speed

17.5 Inch/Min

Figure 5-7: Parameter Guide Setting Examples

4. Press the “OK”

OK

button to exit the Parameter Guide choices.

5. Set the DC Power Supply to obtain the recommended current as noted in the Parameter Guide. Set the

travel speed to the recommended speed per the Parameter Guide.

6. Use the up or down “Mode Selector”

or

buttons to scroll to “<- Back” and press the “OK”

OK

button. You are returned to the main screen highlighting “Parameter Guide”.

7. Use the up or down “Mode Selector”

or

buttons to scroll to Current and press the “OK”

OK

but-

ton. See “Figure 5-8: Current Setting Examples”.

When operating in the “CC” mode, set “Voltage” at any point between 40 - 44 Volts. The Remote Pendant

is set at 42 Volts from the factory.

When working in the “CV” mode, set the “Current”.

CV EXAMPLE:

Electrode Diameter = 1/2” (12.7 mm)
Amperage Required = 850
“OUTPUT LEVEL” setting = 850

ART# A-10829_AB

Current

850A

Menu Setting

Power Mode

CV

Parameter Guide

Figure 5-8: Current Setting Example

8. Use the potentiometer dial

to obtain the correct “Current” setting required when using CV mode.

Press the “OK”

OK

button to set the Current value.