08 duty cycle, Duty cycle -4, Thermal arc 201 ts introduction – Tweco 201 ts Thermal Arc User Manual

Page 16

Advertising
background image

Introduction 2-4

Manual 0-5149

THERMAL ARC 201 TS INTRODUCTION

2.08 Duty Cycle

The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated

welding current output without exceeding the temperature limits of the insulation of the component parts. To

explain the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is

designed to operate at a 20% duty cycle, 200 amperes at 18 volts. This means that it has been designed and

built to provide the rated amperage (200A) for 2 minutes, i.e. arc welding time, out of every 10 minute period

(20% of 10 minutes is 2 minutes). During the other 8 minutes of the 10 minute period the Welding Power

Source must idle and be allowed to cool.

110VAC INPUT

0

10

20

30

40

50

60

70

80

90

100

0

20

40

60

80

100

120

140

160

Welding Current (amps)

Duty Cycle (percentage)@40°

C

Safe

Operating

Region

TIG (GTAW)

Stick (MMA)

Art # A-10141

230VAC INPUT

0

10

20

30

40

50

60

70

80

90

100

0

20

40

60

80

100

120

140

160

180

200

Welding Current (amps)

Duty Cycle (percentage)@40°

C

Safe

Operating

Region

TIG (GTAW)

Art # A-10142

Figure 2-1: Thermal Arc 201 TS Duty Cycle