04 electromagnetic compatibility, Electromagnetic compatibility -3, Installation thermal arc 201 ts – Tweco 201 ts Thermal Arc User Manual

Page 21

Advertising
background image

Manual 0-5149

3-3

Installation, Operation And Setup

INSTALLATION THERMAL ARC 201 TS

NOTE

Damage to the PCA could occur if 265 VAC or higher is applied to the Primary Power Cable.

Model

Primary Supply Lead

Size (Factory Fitted)

Minimum Primary

Current Circuit Size

(Vin/Amps)

Current & Duty Cycle

LIFT TIG/HF TIG

(GTAW)

STICK (MMA)

Thermal Arc

201 TS

H07RN-F 2.5mm²

110V/39A

-

125A @ 25%

110V/30A

160A @ 30%

-

230V/32A

-

200A @ 25%

230V/21A

200A @ 25%

-

Table 3-2: Primary Circuit Sizes to Achieve Maximum Current

3.04 ELECTROMAGNETIC COMPATIBILITY

WARNING

Extra precautions for Electromagnetic Compatibility may be required when this Welding Power

Source is used in a domestic situation.

A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding equipment according to the manufacturer’s

instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of

the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some

cases this remedial action may be as simple as earthing the welding circuit, see NOTE below. In other cases

it could involve constructing an electromagnetic screen enclosing the Welding Power Source and the work,

complete with associated input filters. In all cases, electromagnetic disturbances shall be reduced to the

point where they are no longer troublesome.

NOTE

The welding circuit may or may nor be earthed for safety reasons. Changing the earthing

arrangements should only be authorised by a person who is competent to assess whether the

changes will increase the risk of injury, e.g. by allowing parallel welding current return paths which

may damage the earth circuits of other equipment. Further guidance is given in IEC 60974-13 Arc

Welding Equipment - Installation and use (under preparation).

B. Assessment of Area
Before installing welding equipment, the user shall make an assessment of potential electromagnetic

problems in the surrounding area. The following shall be taken into account

1. Other supply cables, control cables, signalling and telephone cables; above, below and adjacent to the

welding equipment.

2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial equipment.
5. The health of people around, e.g. the use of pacemakers and hearing aids.
6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are to be carried out.
8. The immunity of other equipment in the environment: the user shall ensure that other equipment being

used in the environment is compatible: this may require additional protection measures.

Advertising