Thermal arc 201 ts installation – Tweco 201 ts Thermal Arc User Manual

Page 20

Advertising
background image

Installation, Operation And Setup

3-2

Manual 0-5149

THERMAL ARC 201 TS INSTALLATION

2. Connect ends of line Active (BROWN) and Neutral (BLUE) input conductors to a suitable power suply

system that complies with all applicable local electrical codes.

3. Use Table 3-1 as a guide to select line fuses for the disconnect switch.

Input Voltage

Circuit Breaker or Fuse Size

110V

32A

230V

32A

Table 3-1: Fuse Guide

CAUTION

The time-delay fuses or circuit breaker of an individual branch circuit may have nuisance tripping

when welding with this product due to the amperage rating of the time-delay fuses or circuit

breaker.

Welding Power Supply

Primary Power Cable

Art# A-10143

Figure 3-1 Electrical Input Connections

Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit

provides pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn on

after the input capacitors have charged to operating voltage (after approximately 5 seconds)