07 lift tig / hf tig (gtaw) setup, Lift tig / hf tig (gtaw) setup -7, Installation thermal arc 201 ts – Tweco 201 ts Thermal Arc User Manual

Page 25

Advertising
background image

Manual 0-5149

3-7

Installation, Operation And Setup

INSTALLATION THERMAL ARC 201 TS

3.07 LIFT TIG / HF TIG (GTAW) SETUP

Set Process Selection

Switch to LIFT TIG or HF TIG.

Positive Output

Terminal

(Dinse™ 50)

Negative

Output

Terminal

(Dinse™ 50)

Art # A-10100_AB

Set Welding Current

as specified by the

Electrode Manufacturer.

Secure the gas cylinder in an

upright position by chaining it

to a stationary support to prevent

falling or tipping.

Switch to 2T/4T

Set DOWN Slope

Figure 3-3: Setup for LIFT TIG / HF TIG (GTAW) Welding

LIFT TIG / HF TIG (GTAW) Sequence of Operation

CAUTION

Before any welding is to begin, be sure to wear all appropriate and recommended safety equipment.

1. Switch the ON/OFF Switch (located on the rear panel) to OFF.
2. Connect the ground (work) clamp cable to positive output terminal. It is essential that the male plug is

inserted and turned fully clockwise until connector locks in place to achieve reliable electrical connection.

3. Connect the TIG torch as follows:

a) Place the power cable into the negative output terminal. It is essential that the male plug is inserted

and turned fully clockwise until connector locks in place to achieve reliable electrical connection;

b) Place the 8 pin plug into the 8 pin socket. To make connections, align keyway, insert plug, and rotate

threaded collar fully clockwise.

c) Place the TIG torch gas hose to the gas outlet and tighten with a wrench. Caution: DO NOT over tighten.

4. Using a secured Argon cylinder, slowly crack open then close the cylinder valve while standing off to the

side of the valve. This will remove any debris that may be around the valve & regulator seat area.

5. Install the regulator (for details of VICTOR regulator, please refer to 3.08 ) and tighten with a wrench.
6. Connect one end of the supplied gas hose to the outlet of the Argon regulator and tighten with a wrench.

Caution: DO NOT over tighten.

Advertising