06 stick (smaw) setup, Stick (smaw) setup -6, Thermal arc 95 s installation – Tweco 95 S Thermal Arc(Jan2013) User Manual
Page 24
THERMAL ARC 95 S
INSTALLATION
Manual 0-5086
3-6 Installation
Figure 3-2: Setup for STICK Welding
Stick Mode Sequence of Operation
CAUTION
Before any welding is to begin, be sure to wear all ap-
propriate and recommended safety equipment.
1. Switch the ON/OFF Switch (located on the rear panel)
to OFF.
2. Connect the ground clamp cable to the negative output
terminal, and the electrode holder cable to the positive
output terminal.
NOTE
This set up is known as DC Electrode Positive or reverse
polarity. Please consult with the stick electrode manu-
facturer for specific polarity recommendations.
3.06 STICK (SMAW) Setup
3. Connect the ground clamp to your workpiece.
4. Plug the power cable into the appropriate outlet, and
turn the switch to the “ON” position. The power L.E.D
light should illuminate.
5. Set the “Process Selection Switch” to Stick
6. Set the weld current control knob to the desired
amperage.
7. Install a stick electrode in the electrode holder.
8. You are now ready to begin Stick Welding
NOTE
Gently strike the electrode on the work piece to gener-
ate a welding arc, and slowly move along the work
piece while holding a consistent arc length above base
metal.
200A
Set Welding Current
as specified by the
Electrode Manufacturer.
Set Process Selection
Switch to SMAW (Stick)
Positive Output
Terminal
(Dinse™ 25)
Negative Output
Terminal
(Dinse™ 25)
Art #: A-08602_AC