THERMAL ARC 95 S

INSTALLATION

Manual 0-5086

3-6 Installation

Figure 3-2: Setup for STICK Welding

Stick Mode Sequence of Operation

CAUTION

Before any welding is to begin, be sure to wear all ap-

propriate and recommended safety equipment.

1. Switch the ON/OFF Switch (located on the rear panel)

to OFF.

2. Connect the ground clamp cable to the negative output

terminal, and the electrode holder cable to the positive

output terminal.

NOTE

This set up is known as DC Electrode Positive or reverse

polarity. Please consult with the stick electrode manu-

facturer for specific polarity recommendations.

3.06 STICK (SMAW) Setup

3. Connect the ground clamp to your workpiece.
4. Plug the power cable into the appropriate outlet, and

turn the switch to the “ON” position. The power L.E.D

light should illuminate.

5. Set the “Process Selection Switch” to Stick
6. Set the weld current control knob to the desired

amperage.

7. Install a stick electrode in the electrode holder.
8. You are now ready to begin Stick Welding

NOTE

Gently strike the electrode on the work piece to gener-

ate a welding arc, and slowly move along the work

piece while holding a consistent arc length above base

metal.

200A

Set Welding Current
as specified by the
Electrode Manufacturer.

Set Process Selection
Switch to SMAW (Stick)

Positive Output
Terminal
(Dinse™ 25)

Negative Output
Terminal
(Dinse™ 25)

Art #: A-08602_AC