5.01 Maintenance and Inspection

The only routine maintenance required for the power

supply is a thorough cleaning and inspection, with the

frequency depending on the usage and the operating

environment.

!

WARNING

There are extremely dangerous voltages and

power levels present inside this product.

Disconnect primary power at the source be-

fore opening the enclosure. Wait at least two

minutes before opening the enclosure to allow

the primary capacitors to discharge.

To clean the unit, open the enclosure and use a vacuum

cleaner to remove any accumulated dirt and dust. The unit

should also be wiped clean, if necessary; with solvents

that are recommended for cleaning electrical apparatus.

CAUTION

Do not blow air into the power supply during

cleaning. Blowing air into the unit can cause

metal particles to interfere with sensitive

electrical components and cause damage to

the unit.

SECTION 5:

SERVICE

Warning!

Disconnect input power before maintaining.

Each Use

Visual check of

regulator and pressure

Visual check of torch

Consumable parts

Weekly

Visually inspect

the torch body

and consumables

Visually inspect the

cables and leads.

Replace as needed

3 Months

Clean

exterior

of power supply

6 Months

Replace all

broken parts

Bring the unit to an authorized

Thermal Arc Service Center

to remove any accumulated dirt

and dust from the interior.

This may need to be done more

frequently under exceptionally

dirty conditions.

Maintain more often

if used under severe

conditions

Art # A-08549_AB

Advertising