Section 4:operation, 01 front panel, Section 4:operation -1 – Tweco 95 S Thermal Arc(Jan2013) User Manual

Page 27: Front panel -1, Operation thermal arc 95 s

Advertising
background image

OPERATION

THERMAL ARC 95 S

Operation 4-1

Manual 0-5086

Figure 4-1: 95 S Controls

SECTION 4:

OPERATION

Conventional operating procedures apply when using

the Welding Power Source, i.e. connect work lead

directly to work piece and electrode lead is used to hold

the electrode. The welding current range values should

be used as a guide only. Current delivered to the arc is

dependent on the welding arc voltage, and as welding

arc voltage varies between different classes of electrode,

welding current at any one setting would vary according

to the type of electrode in use. The operator should use

the welding current range values as a guide then fine

tune the welding current to suit the specific application.

Refer to the electrode manufacture's literature for further

information.

4.01 Front Panel

(A) Process Selection Switch
Switches between Lift TIG and STICK Welding modes.
(B) Power On Indicator
The Power ON Indicator illuminates when the ON/OFF

switch is in the ON position and the nominal mains voltage

is present.

(C) Over heat Indicator
The welding power source is protected by a self resetting

thermostat. The indicator will illuminate if the duty cycle

of the power source has been exceeded. If the Over Heat

light illuminates wait for the Over Heat light to extinguish

before resuming welding.
(D) Welding Current Control
The welding current is increased by turning the Weld

Current control knob clockwise or decreased by turning

the Weld Current control knob counterclockwise. The

welding current should be set according to the specific

application. Refer to the electrode manufacture's literature

for further information.
(E) ON/OFF Switch (located on rear panel - not
shown)
This switch controls the Mains Supply Voltage to the

Power Source.

15A

OUTLET

MAX STICK

15A

OUTLET

MAX TIG

Art # A-08707_AB

(A) Process

Selection

Switch

(B) Power On

Indicator

(C) Over Heat

Indicator

(D) Welding

Current

Control

Advertising