Socket Pin

Function

A

Torch Switch Input (24V) to energize weld current.
(connect pins A & B to turn on welding current)

B

Torch Switch Input (0V) to energize weld current
(connect pins A & B to turn on welding current)

C

5k ohm (maximum) connection to 5k ohm remote control potentiometer

D

Zero ohm (minimum) connection to 5k ohm remote control potentiometer

E

Wiper arm connection to 5k ohm remote control potentiometer

G Mains

Earth

F,H,I,J,K,L Not

Used

M

OK to move current detect signal for robotics applications

N

OK to move current detect signal for robotics applications

Table 4-1. Socket Pin Functions


3 Positive Terminal

Welding current flows from the Power Source via heavy duty Dinse type terminal (Size 35-70). It is
essential, however, that the male plug is inserted and turned securely to achieve a sound electrical
connection.

4 Negative Terminal

Welding current flows from the Power Source via heavy duty Dinse type terminal (Size 35-70). It is
essential, however, that the male plug is inserted and turned securely to achieve a sound electrical
connection.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being
fused in the bayonet terminal.

5 Gas Outlet

The Gas Outlet is a BSP-3/8 inch female

gas fitting.

6 ON/OFF Switch

This switch connects the Primary supply voltage to the inverter when in the ON position. This
enables the Power Supply.

WARNING

When the welder is connected to the Primary supply voltage, the internal electrical
components may be at 240V potential with respect to earth.

7 Input Cable

The input cable connects the Primary supply voltage to the equipment.

8 Gas Inlet

The Gas Inlet is a BSP-3/8 inch female gas fitting.