05 guide for selecting filler wire diameter, 06 shielding gas selection – Tweco 300 ACDC Arcmaster User Manual

Page 42

Advertising
background image

36

7.05 Guide for Selecting Filler Wire Diameter

Filler Wire Diameter

AC Current Range

(Amps)

DC Current Range

(Amps)

1/16” (1.6 mm)

30 - 95

20 - 90

3/32” (2.4 mm)

125 - 160

65 - 115

1/8” (3.2 mm)

180 - 240

100 - 165

3/16” (4.8 mm)

220 - 320

200 - 350

Table 7-4. Filler Wire Selection Guide

NOTE

The filler wire diameter specified in Table 10 is a guide only. Other diameter wires may be used
according to the welding application.


7.06 Shielding Gas Selection

Alloy

Shielding Gas

Argoshield is a registered trademark of BOC Gases Limited.

Aluminium & alloys

Welding Argon, Argoshield 80T, 81T

Carbon Steel

Welding Argon

Stainless Steel

Welding Argon, Argoshield 71T, 80T, 81T

Nickel Alloy

Welding Argon, Argoshield 71T

Copper

Welding Argon, Argoshield 81T

Titanium

Welding Argon, Argoshield 80T, 81T

Table 7-5. Shielding Gas Selection


7.07 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe

Electrode Type &

Diameter

Current Range DC

Amperes

Filler Rod for

Root Pass

Joint Preparation

Thoriated 2%

3/32” (2.4 mm)

120 - 170

Yes

Thoriated 2%

3/32” (2.4 mm)

100 - 160

Yes

Thoriated 2%

3/32” (2.4 mm)

90 - 130

No

Table 7-6. TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe