6.06 Save-Load Operation

A total number of 5 programs can be saved into the 300 AC/DC memory.

SAVE

the Current Weld Parameters into Memory

• Press and HOLD the

SAVE

button. Beep will sound and Digital Meter display will show a number 1.

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.
• After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the machine will give a

beep to confirm the weld parameters from the control panel are saved.

LOAD

(retrieve) a Program to Control Panel

• Press and HOLD the

LOAD

button. Beep will sound and Digital Meter display will show a number 1.

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.
• After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the machine will give a beep

to confirm the weld parameters are loaded onto the control panel.