Arcmaster, 300 s, 03 power source problems – Tweco 300 S Arcmaster User Manual

Page 42

Advertising
background image

ARCMASTER

®

300 S

March 31, 2006

10-4

5. Non-metallic parti cles are

trapped in the weld metal
(slag inclusion).

A.

Non-metallic particles may be trapped
in undercut from previous run.

A. If bad undercut is present, clean slag

out and cover with a run from a smaller
diameter electrode.

B. Joint preparation too restricted.

B. Allow for adequate penetration and room

for cleaning out the slag.

C. Irregular deposits allow slag to be

trapped.

C. I f v e r y b a d , c h i p o r g r i n d o u t

irregularities.

D. Lack of penetration with slag trapped

beneath weld bead.

D. Use smaller electrode with sufficient

current to give adequate penetration.
Use suitable tools to remove all slag
from corners.

E.

Rust or mill scale is preventing full
fusion.

E. Clean joint before welding.

F.

Wrong electrode for position in which
welding is done.

F.

Use electrodes designed for position in
which welding is done, otherwise proper
control of slag is diffi cult.

Figure 10 – Examples of slag inclusion

10.03 Power Source Problems

Description

Possible Cause

Remedy

1. The welding arc cannot be

established

A .

B.

The Primary supply voltage has not
been switched ON.

The Welding Power Source switch
is switched OFF.

A .

B.

Switch ON the Primar y supply
voltage.

Switch ON the Welding Power Source.

C.

Loose connections internally.

C.

Have an Accredited Thermal Arc Service
Agent repair the connection.

2. Maximum output welding

current can not be achieved
with nominal Mains supply
voltage.

Defective control circuit

Have an Accredited Thermal Arc Service
Agent inspect then repair the welder.

3. Welding current reduces when

welding

Poor work lead connection to the
work piece.

Ensure that the work lead has a
positive electrical connection to the
work piece.

4. No gas flow when the torch

trigger switch is depressed.

A..

B.

Gas hose is cut.

Gas passage contains impurities.

A..

B.

Replace gas hose.

Disconnect gas hose from the rear of
Power Source then raise gas pressure
and blow out impurities.

C.

Gas regulator turned off.

C.

Turn gas regulator on.

D. Torch trigger s witch lead is

disconnected or switch/cable is
faulty.

D.

Reconnect lead or repair faulty switch/
cable.

Advertising