Arcmaster, 300 s – Tweco 300 S Arcmaster User Manual

Page 49

Advertising
background image

ARCMASTER

®

300 S

March 31, 2006

12-3

E83 error code displayed

No weld current is available.

CPU checks mains supply (input)

voltage when the on/off switch on

rear panel of machine is turned ON.

Buzzer sounds constantly.

Switch machine off then on to reset

E83 error.

E93 error code displayed

Weld current ceases.

Memory chip (EEPROM) on control

PCB can not read/write weld

parameters

Buzzer sounds constantly.

Switch machine off.

E94 error code displayed

Weld current ceases.

Temperature sensor TH1 for IGBTs

or sensor TH2 for secondary diodes

are open circuit

Buzzer sounds constantly.

Switch machine off.

E99 error code displayed

A

M

ain on/off switch on machine has been

turned off

A

Turn on/off switch on.

Weld current ceases.

Mains supply (input) voltage has

been turned off but control circuit

has power from the primary

capacitors

B

M

ains supply (input) voltage has been

turned off

B

Have an Accredited Thermal Arc

Service Agent or a qualified electrician

check the Mains voltage and fuses

Buzzer sounds constantly.

Must switch machine off then on to

reset E99 error.

The Welding Power Source’s

temperature sensors have

malfunctioned.

Have an Accredited Thermal Arc

Service Agent check or replace the

temperature sensors.

Memory chip (EEPROM) error

Have an Accredited Thermal Arc

Service Agent check the control PCB

The Primary supply (input) voltage

fluctuates and is not stable.

Have an Accredited Thermal Arc

Service Agent check connector plug on

input PCB and the Mains voltage

9

10

11

12