Arcmaster, 300 s – Tweco 300 S Arcmaster User Manual

Page 43

Advertising
background image

ARCMASTER

®

300 S

March 31, 2006

11-1

SECTION 11:

VOLTAGE REDUCTION DEVICE (VRD)

11.01 VRD Specifi cation

Description

ArcMaster 400 S

Notes

VRD Open Circuit Voltage

15.3 to 19.8V

Open circuit voltage between welding terminals

VRD Resistance

148 to 193 ohms

The required resistance between welding
terminals to turn ON the welding power

VRD Turn OFF Time

0.2 to 0.3 seconds

The time taken to turn OFF the welding power
once the welding current has stopped

11.02 VRD Maintenance

Routine inspection and testing (power source)

An inspection of the power source, an insulation resistance
test and an earth resistance test shall be carried out.

a) For transportable equipment, at least once every 3

months; and

b) For fi xed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of
the periodic tests.

NOTE

A transportable power source is any equipment
that is not permanently connected and fi xed in
the position in which it is operated.

In addition to the above tests and specifi cally in relation to
the VRD fi tted to this machine, the following periodic tests
should also be conducted by an accredited Thermal Arc
service agent.

Description

IEC 60974-1 Requirements

VRD Open Circuit Voltage

Less than 20V; at Vin=208-230V or 460V

VRD Turn ON Resistance

Less than 200 ohms

VRD Turn OFF Time

Less than 0.3 seconds

If this equipment is used in a hazardous location or environments with a high risk of electrocution then the above tests should
be carried out prior to entering this location.