Arcmaster, 300 s – Tweco 300 S Arcmaster User Manual

Page 47

Advertising
background image

ARCMASTER

®

300 S

March 31, 2006

12-1

SECTION 12:

POWER SOURCE ERROR CODES

sk

r

a

m

e

R

y

d

e

m

e

R

es

u

a

C

el

bi

ss

o

P

n

oit

pi

rc

s

e

D

E01 error code displayed

A

The Welding Power Source’s duty cycle

has been exceeded.

A

Let Power Source cool down then keep

within its duty cycle.

Weld current ceases.

Temperature sensor TH1 (protects

IGBTs) is greater than 80ºC for

B

Fan ceases to operate.

B

Have an Accredited Thermal Arc

Service Agent investigate

Buzzer sounds constantly.

C

Air flow is restricted by vents being

blocked

C

Unblock vents then let Power Source

cool down.

Fan operates at max speed.

E01 resets when TH1 decreases to

70ºC for about 30 seconds.

E02 error code displayed

A

The Welding Power Source’s duty cycle

has been exceeded.

A

Let Power Source cool down then keep

within its duty cycle.

Weld current ceases.

Temperature sensor TH2 (protects

secondary diodes) is greater than

80ºC for about 1 second

B

Fan ceases to operate.

B

Have an Accredited Thermal Arc

Service Agent investigate

Buzzer sounds constantly.

C

Air flow is restricted by vents being

blocked

C

Unblock vents then let Power Source

cool down.

Fan operates at max speed.

E02 resets when TH1 decreases to

70ºC for about 30 seconds.

E03 error code displayed

A

Primary current is too high because

welding arc is too long.

A

Reduce length of welding arc.

Weld current ceases.

Primary (input) current too high

B

Mains supply voltage is more than 10%

below nominal voltage

B

Have an Accredited Thermal Arc

Service Agent or a qualified electrician

check for low Mains voltage.

Buzzer sounds constantly.

Switch machine off then on to reset

E03 error.

E11 error code displayed

Weld current ceases.

Over Primary supply (input) voltage

at primary capacitors is exceeded

for one second

Buzzer sounds constantly.

Error code E11 automatically will

reset when the voltage reduces.

Primary supply voltage is greater than

the nominal voltage plus 10%

Have an Accredited Thermal Arc

Service Agent or a qualified electrician

check the Primary voltage.

1