05 machine specifications, 05 machine specifications -3 – Tweco 180 Portable MIG User Manual

Page 19

Advertising
background image

INTRODUCTION

FABRICATOR 140, 180

July 20, 2007

2-3

Manual 0-4991

2.05 Machine Specifications

Description

Fabricator 140

Fabricator 180

Package System Part Number

W1002500

W1002600

Power Source Weight

64 lb (29 kg)

80 lb (36 kg)

Power Source Dimensions HxWxD

Number of Phases
Frequency
Flexible Supply Cable Size

7 ft (2.3 m) 14AWG

8 ft (2.5 m) 12AWG

Supply Lead Plug Type

5-15P

6-50P

Nominal Input Voltage

120V AC

230V AC

Rated Input Current

^ 15A

^ 21A

Rated kVA @ 100% Duty Cycle

1kVA

1.9kVA

Rated Input Current

15A (65A@40%)

21A

(130A@25%)

Maximum Input Current

24A (90A@20%)

31A (180A@15%)

Generator Requirements

# 6kVA

# 8.5kVA

Supply VA @ max. output

# 5.1kVA

# 7kVA

Open Circuit Voltage Range

20.5 – 34V

19.5 – 38V

Output Current Range

30 – 140A

30 – 180A

Duty Cycle Period
Number of Output Voltage Values

4

6

Minimum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)

(+) 15A (65A@40%)

(+) 21A (130A@25%)

Maximum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)

(+) 24A (90A@20%)

(+) 31A (180A@15%)

Wire Size Range

Steel

Stainless Steel

.023” - .030”

(0.6 - 0.8mm)

.023” - .030” - .035"

(0.6 - 0.8 - 0.9mm)

Flux Core

.030” - .035”

(0.8 - 0.9mm)

.030” - .035” - .045"

(0.8 - 0.9 - 1.2mm)

Aluminum

.030” - .035” (0.8 - 0.9mm)

.023” - .030” - .035"

(0.6 - 0.8 - 0.9mm)

15.8 x 10.0 x 21.3”

400 x 255 x 540mm

1 Ø

10 Minutes

60Hz

^ The Rated Input Current should be used for the determination of cable size & supply requirements.

+ Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for

your situation in this regard.

# Generator Requirements at the Maximum Output Duty Cycle.

Table 2-1: Specifications