MAINTENANCE

FABRICATOR 140, 180

July 20, 2007

5-5

Manual 0-4991

5.06 Power Source Problems

FAULT

CAUSE

REMEDY

1 Primary line voltage is

ON. Welding arc can not
be established.

A Primary fuse is blown.

A Replace primary fuse.

B Broken connection in primary

circuit.

B Have an Accredited THERMAL ARC Service Agent check

primary circuit.

2 Primary line voltage is

ON but when the MIG
Gun trigger switch is
depressed nothing
happens.

MIG Gun trigger switch leads

are disconnected.

Reconnect.

3 Primary line voltage is

ON, no wire feed but gas
flows from the MIG Gun
when the torch trigger
switch is depressed.

A Electrode wire stuck in wire

liner or contact tip (burn-back
jam).

A Check for clogged / kinked MIG Gun wire liner or worn

contact tip. Replace faulty component(s).

B Faulty control PCB

B Have an Accredited THERMAL ARC Service Agent

investigate the fault.

4 Wire feeds when the MIG

Gun trigger switch is
depressed but arc can
not be established.

Poor or no work lead
connection.

Clean work clamp area and ensure good electrical contact.

5 Jerky wire feed

A Worn or dirty contact tip

A Replace

B Worn feed roller.

B Replace

C Excessive back tension from

wire reel hub.

C Reduce brake tension on spool hub

D Worn, kinked or dirty conduit

liner

D Clean or replace conduit liner

6 No gas flow

A Gas hose is cut.

A Replace or repair.

B Gas passage contains

impurities.

B Disconnect gas hose from the rear of FABRICATOR then

raise gas pressure and blow out the impurities.

C Gas regulator turned off.

C Turn on.

7 Gas flow continues after

the MIG Gun trigger
switch has been
released.

Gas valve has jammed open

due to impurities in the gas or
the gas line.

Have an Accredited THERMAL ARC Service Agent repair or

replace gas valve.

Table 5-2: Power Source Problems