Tweco 180 Portable MIG User Manual

Page 54

Advertising
background image

FABRICATOR 140, 180

MAINTENANCE

Manual 0-4991

5-4

July 20, 2007

FAULT

CAUSE

REMEDY

6 Weld cracking

A Weld beads too small

A Decrease travel speed

B Weld penetration

narrow and deep

B Reduce current and voltage and increase MIG

torch travel speed or select a lower penetration
shielding gas.

C Excessive weld

stresses

C Increase weld metal strength or revise design

D Excessive voltage

D Decrease voltage by reducing the voltage

selection switch.

E Cooling rate too fast

E Slow the cooling rate by preheating part to be

welded or cool slowly.

7 Cold weld puddle

A Faulty rectifier unit

A Have an Accredited THERMAL ARC Service

Agent to test then replace the faulty
component.

B Loose welding cable

connection.

B Check all welding cable connections.

C Low Primary Voltage

C Contact supply authority

8 Arc does not have a crisp

sound that short arc
exhibits when the
wirefeed speed and
voltage are adjusted
correctly.

The MIG torch has been
connected to the wrong
voltage polarity on the
front panel.

Connect the MIG torch to the positive (+)

welding terminal for solid wires and gas
shielded flux cored wires. Refer to the electrode
wire manufacturer for the correct polarity.

Table 5-1b: Welding Problems Continued