06 power-master 500 specifications, 06 power-master 500 specifications -4 – Tweco 500P PowerMaster User Manual

Page 20

Advertising
background image

POWERMASTER 500, 500P, 350

INTRODUCTION

2-4

Manual No. 0-4749

Line Voltage

Line Current

kVA

Eff.

PF

Output

208 VAC/3 Phase

68 Amps

24.5

89%

0.83 450A/38V/100% Duty Cycle

230 VAC/3 Phase

62 Amps

24.7

90%

0.82 450A/38V/100% Duty Cycle

380 VAC/3 Phase

40 Amps

23.7

89%

0.84 450A/38V/100% Duty Cycle

400 VAC/3 Phase

35 Amps

24.2

90%

0.84 450A/38V/100% Duty Cycle

460 VAC/3 Phase

30 Amps

23.9

91%

0.84 450A/38V/100% Duty Cycle

208 VAC/3 Phase

88 Amps

31.7

89%

0.88 500A/40.0/60% Duty Cycle

230 VAC/3 Phase

82 Amps

32.7

89%

0.87 500A/40.0/60% Duty Cycle

380 VAC/3 Phase

50 Amps

32.9

88%

0.87 480A/39.2/60% Duty Cycle

400 VAC/3 Phase

43 Amps

29.8

91%

0.86 480A/39.2/60% Duty Cycle

460 VAC/3 Phase

39 Amps

31.1

90%

0.88 500A/40.0/60% Duty Cycle

Input Data

25.5 in /
64.7 cm

26.8 in /
68.0 cm

23.0 in / 58.4 cm

22.5 in / 57.1 cm

14.9 in /
378.5 mm

Art # A-06852

Net Weight: 154 lbs / 70 kg

WARNING

POWER

10A

REMOTE

LOCAL

CONTACTOR

Line Frequency:

50/60 HZ

Out put Current Range:

5 – 560 Amps

Out put Voltage Range:

10 – 44 Volts

Maximum Output Current:

600 Amps

Maximum Open Circuit Voltage (OCV):

70 Volts (57 Volts for CCC)

Operating Temperature Range:

32-104°F

Input Line Variations:

± 10%

Line Regulation:

± 1%

Load Regulation:

± 1%

Water Protection Class:

IP23S

Figure 2-3: Power-Master 500 Dimensions and Weight

2.06 Power-Master 500 Specifications

Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the specifications or
design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold or shipped to the

corresponding changes, updates, improvements or replacement of such items.

Advertising