07 power-master 350 specifications, 08 general: power-master 500p, 07 power-master 350 specifications -5 – Tweco 500P PowerMaster User Manual
Page 21

POWERMASTER 500, 500P, 350
Manual No. 0-4749
2-5
INTRODUCTION
25.5 in /
64.7 cm
26.8 in /
68.0 cm
23.0 in / 58.4 cm
22.5 in / 57.1 cm
14.9 in /
378.5 mm
Art # A-06853
Net Weight: 154 lbs / 70 kg
WARNING
POWER
10A
REMOTE
LOCAL
CONTACTOR
350
350
350
350
Figure 2-4: Power-Master 350 Dimensions and Weight
2.07 Power-Master 350 Specifications
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the specifications or design
of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold or shipped to the corresponding
changes, updates, improvements or replacement of such items.
Line Frequency:
50/60 HZ
Out put Current Range:
5 – 560 Amps
Out put Voltage Range:
10 – 44 Volts
Maximum Output Current:
600 Amps
Maximum Open Circuit Voltage (OCV):
70 Volts (57 Volts for CCC)
Operating Temperature Range:
32-104°F
Input Line Variations:
± 10%
Line Regulation:
± 1%
Load Regulation:
± 1%
Water Protection Class:
IP23S
Line Voltage
Line Current
kVA
Eff.
PF
Output
208 VAC/3 Phase
37 Amps
13.1
89%
0.83 300A/32V/100% Duty Cycle
230 VAC/3 Phase
33 Amps
13.1
89%
0.82 300A/32V/100% Duty Cycle
380 VAC/3 Phase
24 Amps
15.8
88%
0.82 300A/32V/100% Duty Cycle
400 VAC/3 Phase
19 Amps
13.1
89%
0.84 300A/32V/100% Duty Cycle
460 VAC/3 Phase
17 Amps
13.1
89%
0.84 300A/32V/100% Duty Cycle
208 VAC/3 Phase
43 Amps
15.4
89%
0.88 350A/34V/60% Duty Cycle
230 VAC/3 Phase
39 Amps
15.4
89%
0.87 350A/34V/60% Duty Cycle
380 VAC/3 Phase
28 Amps
18.4
88%
0.85 350A/34V/60% Duty Cycle
400 VAC/3 Phase
23 Amps
15.4
91%
0.86 350A/34V/60% Duty Cycle
460 VAC/3 Phase
20 Amps
15.4
90%
0.88 350A/34V/60% Duty Cycle
Input Data