Tweco 500P PowerMaster User Manual

Page 27

Advertising
background image

POWERMASTER 500, 500P, 350

Manual No. 0-4749

3-3

INSTALLATION

Line

Volts

Rated Line

Amps

Approx. Line

Fuse Size Amps Copper Line Wire Size*

Copper Gounding

Conductor Min. Size

208

88

100

6 AWG (16 mm

2

)

6 AWG (16 mm

2

)

230

82

100

6 AWG (16 mm

2

)

6 AWG (16 mm

2

)

380

50

60

10 AWG (6 mm

2

)

10 AWG (6 mm

2

)

400

43

60

10 AWG (6 mm

2

)

10 AWG (6 mm

2

)

460

39

60

10 AWG (6 mm

2

)

10 AWG (6 mm

2

)

Table 3-1 Recommended Wire and Fuse Size Table For PowerMaster 500/500P

Line

Volts

Rated Line

Amps

Approx. Line

Fuse Size Amps Copper Line Wire Size*

Copper Gounding

Conductor Min. Size

208

58

60

10 AWG (6 mm

2

)

10 AWG (6 mm

2

)

230

54

60

10 AWG (6 mm

2

)

10 AWG (6 mm

2

)

380

31

40

12 AWG (4 mm

2

)

12 AWG (4 mm

2

)

400

29

40

12 AWG (4 mm

2

)

12 AWG (4 mm

2

)

460

26

40

12 AWG (4 mm

2

)

12 AWG (4 mm

2

)

Table 3-2 Recommended Wire and Fuse Size Table For PowerMaster 350

*Conductor size shall be modified as required for line voltage and ambient temperature. Sizes listed are based on
194°F (90°C) conductor insulation, designated as FEP, FEPB, RHH, and THHN.