04 rear panel (all models), 04 rear panel (all models) -6 – Tweco 500P PowerMaster User Manual

Page 38

Advertising
background image

POWERMASTER 500, 500P, 350

OPERATION

4-6

Manual No. 0-4749

4.04 Rear Panel (All Models)

St. Louis, MO USA

MADE IN MALAYSIA

WELDING OUTPUT

75V

ENERGY INPUT

50/60HZ

3

U

1

I

1MAX

I

1eff

208 V

230 V
400 V
460 V

88
82

43
39

68
64

33
30

IP23S

50/60HZ

1

AUXILLARY POWER OUTPUT

120 V
24 V

10A
10A

100%
100%

F1

F2

S

5

1

2

3

4

5

Art # A-06859

6

Figure 4-3: Rear Panel

1. 14 Pin Receptacle: This receptacle allows the power

source to interface with wire feeders, and remote
controls such as a foot pedal. This receptacle provides
auxiliary power, contactor control for energizing the
output of the power source, and remote output control.
The pinout is as follows:

A) 24 VAC auxiliary power high side

B) 24 VAC Contactor circuit, (closure between pin A

and pin B will energize output).

C) Remote control maximum (top side of remote

control)

D) Control circuit common

E) Remote control in (wiper of remote pot., 0 to 10

Volts). CV mode: 0 to 10 Volts gives 10 – 44 Volts
of output. CC mode: 0 to 10 Volts gives 5 – 560
Amps of output.

F) Scaled output current signal: Ifb = 100 Amps/Volt

G) 24/115 VAC neutral

H) Output voltage signal: 10 Volts/Volt

I) 115 VAC auxiliary power high side

J) 115 VAC Contactor circuit, (closure between pin I

and pin J will energize output).

K) Chassis ground

L) N/C

M) N/C

N) N/C

2. 19 Pin Receptacle: This receptacle allows the power

source to interface with wire feeders, and remote
controls such as a foot pedal. This receptacle provides
auxiliary power, contactor control for energizing the
output of the power source, and remote output control.
The pinout is as follows:

A) Contactor circuit (+15 Volts)

B) Contactor circuit in, (closure between pin A and

pin B will energize output).

C) Scaled output voltage signal: Vfb = 10 Arc Volts/

Volt

D) 24 VAC auxiliary power high side

E) 115 VAC auxiliary power high side

F) 24/115 VAC neutral

G) Chassis ground

H) Remote control maximum (top side of remote pot.)

J) Remote control in (wiper of remote pot., 0 to 10

Volts). CV Mode: 0 to 10 Volts gives 0 – 44 Volts
of output. CC Mode: 0 to 10 Volts gives 0 – 560
Amps of output.

K) Remote control minimum (bottom side of remote

pot.)

L) Control circuit common

M) Arc Established = +12 Volts

N) Control circuit common

Advertising