Section 3: installation, 01 location, 02 voltage changeover – Tweco 500P PowerMaster User Manual

Page 25: Section 3, Installation -1, 01 location -1 3.02 voltage changeover -1

Advertising
background image

POWERMASTER 500, 500P, 350

Manual No. 0-4749

3-1

INSTALLATION

SECTION 3:

INSTALLATION

3.01 Location

Adequate air circulation is needed at all times in order to
assure proper operation. Provide a minimum of 12 inches
(305 mm) of free airspace on all sides of the unit. Make
sure that the ventilator openings are not obstructed.
Ventilation air flow is from rear to side.

3.02 Voltage Changeover

For proper operation and to prevent damage to the
machine, the voltage changeover must be set according
to the incoming AC line voltage. Remove the left side panel
of the machine to gain access to the voltage changeover
board. Set the links to agree with one of the four available
voltage settings. (See Figures 3-1 through 3-4).

The four settings are:

200 VAC

230 VAC

400VAC / 380VAC

460 VAC

1. Check the name plate of the machine for proper line

voltage.

2. Move the voltage links by loosening the nuts

securing the links in place. For 200 and 230 VAC
settings place the two links in the 200/230V positions.
For 380 /400 and 460 VAC settings place the two links
directly on top of each other in the 400/460V
position. See figures 3-1 through 3-4. Make sure that
the connections are properly tightened.

DANGER

ELECTRIC SHOCK CAN KILL.

Open the main wall disconnect switch or
breaker, before removing any covers or
access panels on the welding machine. Live
voltage is still present even with the front panel
control switch OFF. Wait at least three full
minutes after power has been removed
before removing any covers or access panels
to allow adequate time for internal capacitors
to discharge.

E4

200 VOLT CONNECTION

460

E2

400

E3

230

460

E1

400

Art # A-04083

Figure 3-1

230 VOLT CONNECTION

400

460

E2

E3

E4

E1

460

200

400

Art # A-04084

Figure 3-2

E4

380 / 400 VOLT CONNECTION

200

200

E2

230

E3

230

E1

230

460

200

Art # A-04085

Figure 3-3

460 VOLT CONNECTION

200

200

E2

230

E3

230

E4

E1

230

200

400

Art # A-04086

Figure 3-4