04 power source problems, 04 power source problems -4 – Tweco 500P PowerMaster User Manual

Page 46

Advertising
background image

POWERMASTER 500, 500P, 350

SERVICE

5-4

Manual No. 0-4749

5.04 Power Source Problems

FAULT CAUSE REMEDY

1 Mains supply voltage is ON.

Digital meter if off and
welding arc can not be
established.
.

A

B


C

D

E


F

Primary fuse is blown.

Broken connection in
primary circuit.

Voltage links not set
correctly

Control POWER switch is
OFF

Control POWER switch is
faulty

Possibly defective main
control board or display
board

A

B

C

D

E

F

Replace primary fuse.

Have an Accredited Thermal Arc
Service Provider check primary
circuit.

Correct voltage links

Turn switch ON

Have an Accredited Thermal Arc
Service Provider replace the
switch

Have an Accredited Thermal Arc
Service Provider replace the
board(s)

2 Power Source blows input

fuse as soon as power is
applied

A

B

C

D



E

Incorrect input wiring

Voltage links not set
correctly

Control fuse blown

Internal wiring to terminal
block, input rectifier,
IGBT’s, contactors or
changeover board faulty

Possible defective input
rectifier, suppressor, IGBT,
or capacitor board

A

B

C

D


E

Correct input wiring

Correct voltage links

Replace

Have an Accredited Thermal Arc
Service Provider repair the
wiring

Have an Accredited Thermal Arc
Service Provider replace the
components(s) / board(s)

3 Power Source powers up

but fans do not run

A

B

C

Control switch is OFF

No 120VAC on rear outlet

Faulty wiring

A

B

C

Turn switch ON

Replace 20A fuse on rear panel

Have an Accredited Thermal Arc
Service Provider repair the
wiring to fans or main control
board J9

4 Power Source powers up

but fans do not run

D

E

Defective main control pcb

Possible faulty fan(s)

D

E

Have an Accredited Thermal Arc
Service Provider replace pcb

Have an Accredited Thermal Arc
Service Provider replace the
fan(s)