Tweco 7-3443 User Manual

Page 2

Advertising
background image

October 6, 2004

2

Manual 0-2771

Torch Control

Connectors

Pilot Lead (+)

Torch Lead Assembly

Negative/Plasma Lead

Art # A-04208

Adapter Fitting

8" Control Connector

Wires with Connectors

To

Po

we

r Supply

(-) Fitting

To

Po

we

r Supply

Control Connector

To

Po

wer Supply

Pilot Connector

Fastons

Joined and

Sleeved Wires

RPT Adapter Connections, Control Connector for PAK-4Xi, 6Xi, 2XT-220 and DynaPak 110 Shown

CAUTION

Refer to the illustration above. Torch leads may include two wires connected with mating connectors and
covered with an insulation sleeve. On these leads the wires must remain covered and connected in hand torch
applications.

7. Connect the Negative/Plasma Lead from the replacement torch to the Adapter Fitting. Slide the protec-

tive boot over the lead connection.

8. Connect the Control Connector Wire (see NOTE) to the two mating connectors on the replacement torch

leads per one of the following procedures:

For PAK-4Xi, 6Xi, 2XT-220 and DynaPak 110:

Connect the Control Connector Wires (8” long), with two connectors, to the two mating connectors on
the replacement torch leads. Refer to Illustration.

For Pak Master 25 & 38XL, EconoPak 25 and Drag-gun 38:

Connect the Short Control Connector Wire (3” long), with two connectors, to the two mating connec-
tors on the replacement torch leads.

NOTE

For Mechanized Systems refer to the Torch Control Cable Wiring Diagram in the Manual supplied with the
RPT Torch.

9. Connect the fastons of the Control Connector Wires to the Power Supply.

Advertising