Tweco M-42 RPT User Manual

Page 16

Advertising
background image

January 23, 2004

16

Manual 0-2856

WARNING - Replacing Original Machine Torch with RPT Mechanized Torch

Thermal Dynamics RPT mechanized torches have two control wires that are used for Parts - In - Place (PIP) only.
Do not connect these PIP connections directly into any start input because when the torch parts are in place, the
start signal will always be energized. If the torch parts are not in place but are subsequently installed with the start
signal energized, the shield cup will complete the start circuit and the unit will immediately transfer a pilot arc.

Standard Torch Control Cable For Start / Stop Only Mechanized Systems

Art # A-03763

Control Connector

Plug with Connectors

To Power Supply

Control Connector

To Torch

Control Device

Standard Torch

Control Cable

NOTE: These wires are not present
in all configurations. If present,
leave them connected together.

NOTE

Control wires have various
types of connectors or plugs.

Optional Torch Control Cable For CNC / Remote Pendant Systems

This option is to be used with Thermal Dynamics XR's, XL's and XL Plus Systems Only

Torch Control

Connectors

Torch Lead

Assembly

Art # A-03819

Control Connector

Plug with Connectors

To Power Supply

Control Connector

To Torch

Control Device

Torch Control

Cable

Control Shield

Connector

Lead Shield

Connector

Connectors only on

Shielded Leads

NOTE: These wires are
not present in all
configurations.
If present, leave them
connected together.

NOTE

Shielded Leads are available only for Thermal Dynamics Product and are not to be installed on any other products.