January 23, 2004

2

Manual 0-2856

2. Machine Torches

Available with fiberglass mounting tube & rack
and phenolic (plastic) pinch block assembly.

A-02812

B. Torch Leads Lengths

• Hand Torches:

20 ft (6.1 m) or 50 ft (15.2 m)

• Machine Torches:

25 ft (7.6 m) or 50 ft (15.2 m)

C. Torch Ratings

Ambient

Temperature

104° F

(40° C)

Duty Cycle

100% @ 40 Amps @ 200 scfh

Maximum Current

40 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

12 kV

Torch Ratings

NOTE

Power Supply characteristics will determine ma-
terial thickness range.

D. Torch Parts

Gas Distributor, Electrode, Tip, Shield Cup

E. Parts - In - Place (PIP)

The torch head has built - in contacts called Parts - In
- Place (PIP). These two contacts are made through
the inside of the shield cup when it is installed. The
torch will fail to operate if these contacts are not made.

A-00458

Torch Switch

PIP Pin

PIP Pin

Shield Cup

To Control

Cable Wiring

PIP Circuit - Machine Torch

A-03540

Torch Trigger

PIP Pins

Shield Cup

To Control

Cable Wiring

Torch Switch

PIP Circuit - Hand Torch

F. Gas Requirement

1. Single Plasma / Secondary Gas

Compressed Air

2. Pressure

70 psi (4.8 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar)

3. Total Flow

Cutting: 200 scfh (94.4 lpm)

Gouging: 230 scfh (108.5 lpm)

scfh = standard cubic feet per hour