Shield – Tweco Torch Data for Auto-Cut O2 V.2 User Manual

Page 12

Advertising
background image

TORCH DATA for AutoCut O

2

8-12

Manual 0-4832 Rev AF

(ga)

(in)

inch

(PSI)

Ball

(PSI) Ball

(PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

40

65

120

59

120

148

0.130

50

0.250

0.3

0.090

1/2

0.500

40

65

120

81

120

158

0.130

37

0.250

0.5

0.100

5/8

0.625

40

65

120

43

120

172

0.140

26

0.250

0.6

0.115

(Bar)

Ball

(Bar) Ball

(Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

2.8

65

8.2

59

8.2

149

3.3

1220

6.4

0.3

2.3

2.8

65

8.2

81

8.2

156

3.3

1010

6.4

0.5

2.5

2.8

65

8.2

43

8.2

168

3.5

740

6.4

0.6

2.8

BOLD TYPE indicates maximum piercing parameters.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later

(mm)

10

12
15

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield (N

2

)

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield (N

2

)

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

36-1041

36-1080

36-1020

36-1016

36-1034

36-1274

36-1062

Stainless Steel
100A
H35 Plasma / N

2

Shield

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Plasma Gas

Distributor

Electrode

Cartridge

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB