Stainless steel 200a n, Plasma / h, O shield – Tweco Torch Data for Auto-Cut O2 V.2 User Manual

Page 27

Advertising
background image

Manual 0-4832 Rev AF

8-27

TORCH DATA for AutoCut O

2

(ga)

(in)

inch

(PSI)

(Ball) (PSI) (Ball) (PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

20

80

90

5

55

155

0.160

95

0.300

0.0

0.110

1/2

0.500

20

80

90

5

55

156

0.160

85

0.300

0.4

0.115

5/8

0.625

20

80

90

5

55

158

0.180

65

0.300

0.5

0.122

3/4

0.750

20

80

90

5

55

163

0.200

50

0.300

0.7

0.133

7/8

0.875

20

80

90

5

55

177

0.250

40

0.400

0.9

0.149

1

1.000

20

80

90

5

55

183

0.300

35

0.450

1.0

0.148

1 1/4

1.250

20

80

90

5

55

185

0.300

20

0.176

1 1/2

1.500

20

80

90

5

55

200

0.350

10

0.211

1 3/4

1.750

20

80

90

5

55

207

0.350

8

0.216

(Bar)

(Ball) (Bar) (Ball) (Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

80

6.3

5

3.8

155

4.1

2400

7.6

0.0

2.8

1.4

80

6.3

5

3.8

156

4.1

2000

7.6

0.4

2.9

1.4

80

6.3

5

3.8

157

4.4

1550

7.6

0.5

3.1

1.4

80

6.3

5

3.8

165

5.1

1100

7.6

0.7

3.4

1.4

80

6.3

5

3.8

183

7.6

900

11.4

0.9

3.7

1.4

80

6.3

5

3.8

185

7.6

500

4.5

1.4

80

6.3

5

3.8

200

8.9

250

5.4

1.4

80

6.3

5

3.8

206

8.9

200

5.5

Stainless Steel
200A
N

2

Plasma / H

2

O Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.

44

Edge Start

25

32

38

Edge Start

Edge Start

Edge Start

10

12

15

20

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield

(H

2

O)*

(mm)

Edge Start

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield

(H

2

O)*

Edge Start

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

36-1048

36-1089

36-1020

36-1016

36-1039

36-1273

36-1064

* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.

Plasma Gas

Distributor

Electrode

Cartridge

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB

Advertising