Stainless steel 200a n, Plasma / h, O shield – Tweco XT-300 Torch Data for Distributor Ultra-Cut 150 & 200 Power Supply AJ User Manual

Page 21

Advertising
background image

Manual 0-4801 Rev. AJ

8-21

TORCH DATA

(ga)

(in)

inch

(PSI)

(Ball) (PSI) (Ball) (PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

20

80

90

5

55

155

0.160

95

0.300

0.0

0.110

1/2

0.500

20

80

90

5

55

156

0.160

85

0.300

0.4

0.115

5/8

0.625

20

80

90

5

55

158

0.180

65

0.300

0.5

0.122

3/4

0.750

20

80

90

5

55

163

0.200

50

0.300

0.7

0.133

7/8

0.875

20

80

90

5

55

177

0.250

40

0.400

0.9

0.149

1

1.000

20

80

90

5

55

183

0.300

35

0.450

1.0

0.148

1 1/4

1.250

20

80

90

5

55

185

0.300

20

0.176

1 1/2

1.500

20

80

90

5

55

200

0.350

10

0.211

1 3/4

1.750

20

80

90

5

55

207

0.350

8

0.216

(Bar)

(Ball) (Bar) (Ball) (Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

80

6.3

5

3.8

155

4.1

2400

7.6

0.0

2.8

1.4

80

6.3

5

3.8

156

4.1

2000

7.6

0.4

2.9

1.4

80

6.3

5

3.8

157

4.4

1550

7.6

0.5

3.1

1.4

80

6.3

5

3.8

165

5.1

1100

7.6

0.7

3.4

1.4

80

6.3

5

3.8

183

7.6

900

11.4

0.9

3.7

1.4

80

6.3

5

3.8

185

7.6

500

4.5

1.4

80

6.3

5

3.8

200

8.9

250

5.4

1.4

80

6.3

5

3.8

206

8.9

200

5.5

* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.

Note2: Water source used for shield must be demineralized.

Stainless Steel
200A
N

2

Plasma / H

2

O Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.

Edge Start

Edge Start

25

32

44

Pre Flow

Pressure

(N

2

)

Edge Start

Edge Start

Edge Start

Edge Start

21-1022

21-1015

21-1049

21-1284

21-1067

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

21-1043

21-1089

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Shield

(H

2

O)*

38

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

10

12

(mm)

20

15

Material

Thickness

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield

(H

2

O)*

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Cartridge

Electrode

Shield

Shield Gas
Distributor

Tip

Plasma Gas

Distributor

Shield Retainer

Art # A-07917_AC

This Art Is For Reference ONLY

Advertising