Aluminum 150a n, Plasma / h, O shield – Tweco XT-300 Torch Data for Distributor Ultra-Cut 150 & 200 Power Supply AJ User Manual

Page 31

Advertising
background image

Manual 0-4801 Rev. AJ

8-31

TORCH DATA

Aluminum

150A

N

2

Plasma / H

2

O Shield

Cartridge

21-1020

Electrode

21-1081

Plasma

Gas Distributor

21-1041

Tip

21-1092

Shield Cup

21-1016

Art # A-06785

Shield

Gas Distributor

21-1278

Shield Cap

21-1048

(in)

inch

(PSI)

Ball

(PSI)

Ball

(PSI) *

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/16

0.188

70

60

90

8

55

130

0.100

150

0.350

0.2

0.107

1/4

0.250

70

60

90

8

55

133

0.120

120

0.350

0.2

0.108

3/8

0.375

70

60

90

8

55

140

0.120

100

0.350

0.2

0.116

1/2

0.500

70

60

90

8

55

152

0.200

75

0.350

0.3

0.126

5/8

0.625

70

60

90

8

55

155

0.200

50

0.350

0.4

0.142

3/4

0.750

70

60

90

8

55

165

0.250

35

0.350

0.5

0.141

1

1.000

70

60

90

8

55

178

0.300

20

0.350

1.0

0.155

(Bar)

Ball

(Bar)

Ball

(Bar) *

Volts

(mm)

±0.1

(mm/mi

n)

(mm)

(sec)

(mm)

4.8

60

6.2

8

3.8

130

2.5

3700

8.9

0.2

2.7

4.8

60

6.2

8

3.8

132

3.0

3220

8.9

0.2

2.7

4.8

60

6.2

8

3.8

137

3.0

2785

8.9

0.2

2.8

4.8

60

6.2

8

3.8

142

3.0

2445

8.9

0.2

2.9

4.8

60

6.2

8

3.8

149

5.1

2050

8.9

0.3

3.2

4.8

60

6.2

8

3.8

154

5.1

1445

8.9

0.4

3.4

4.8

60

6.2

8

3.8

167

6.4

830

8.9

0.5

3.7

4.8

60

6.2

8

3.8

177

7.6

535

8.9

1.0

3.9

NOTE 1: Ohmic height sensing is not recommended with water shield.
Water on the plate interferes electrically with the ohmic sensing circuit.

* Pressure of the water supply line should be regulated by customer supplied pressure regulator

12
15
20
25

5
6
8

10

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Material

Thickness

Pre Flow

Pressure

(N

2

)

Plasma (N

2

) Shield

(H

2

O)

Torch

Working

Height

Cut Flow Rates / Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

NOTE 2: Water source used for H

2

O Water Shield must be demineralized.

Kerf

Width

@ Rec.

Speed

150A Aluminum (N

2

/H

2

O)

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates / Pressures

Arc

Voltage

Kerf

Width

@ Rec.

Speed

Plasma (N

2

) Shield

(H

2

O)

Advertising