Shield, This art is for reference only – Tweco XT-301 Torch Data for Distributor Use w- Auto-Cut 20 O2 AG User Manual

Page 11

Advertising
background image

Torch Data

8-11

Manual 0-4821 Rev. AG

(ga)

(in)

inch

(PSI)

Ball

(PSI)

Ball

(PSI)

Volts

(in)

±0.005

(ipm )

(in)

(s ec)

(in)

3/8

0.375

40

65

120

59

120

148

0.130

50

0.250

0.3

0.090

1/2

0.500

40

65

120

81

120

158

0.130

37

0.250

0.5

0.100

5/8

0.625

40

65

120

43

120

172

0.140

26

0.250

0.6

0.115

(Bar)

Ball

(Bar)

Ball

(Bar)

Volts

(m m )

±0.1

(mm/min)

(m m )

(s ec)

(m m )

2.8

65

8.2

59

8.2

149

3.3

1220

6.4

0.3

2.3

2.8

65

8.2

81

8.2

156

3.3

1010

6.4

0.5

2.5

2.8

65

8.2

43

8.2

168

3.5

740

6.4

0.6

2.8

Stainless Steel
100A
H35 Plasma / N

2

Shield

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Plasma Gas

Distributor

Electrode

Cartridge

35-1041

35-1080

35-1020

35-1016

35-1034

35-1274

35-1062

Material

Thicknes s

Pre Flow

Pres s ure

(N

2

)

Cut Flow Rates /

Pres s ures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plas m a

(H35)

Shield (N

2

)

Material

Thicknes s

Pre Flow

Pres s ure

(N

2

)

Cut Flow Rates /

Pres s ures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plas m a

(H35)

Shield (N

2

)

BOLD TYPE indicates m axim um piercing param eters .
Requires CCM vers ion 3.4 or later. Requires GCM vers ion 3.2 or later

(m m )

10

12
15

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB

Advertising