Viking Pump TSM320.1: C-FH 56/456 User Manual
Technical service manual, Contents introduction, Special information
SECTION TSM 320.1
PAGE
1 Of 7
ISSUE
E
VIKING PUMP, INC.
•
A Unit of IDEX Corporation
•
Cedar Falls, IA 50613 USA
TECHNICAL SERVICE MANUAL
CONTENTS
INTRODUCTION
The illustrations used in this maintenance bulletin are for
identification purposes only and
should not be used for
ordering parts. Secure a parts list from the factory or a
Viking representative. Always give complete name of part,
part number and material with the model and serial number
of the pump when ordering repair parts.
fIgURE 1
SERIES 56M aND 456M PUMP
(3 gPM Size Shown)
Packed Or Mechanical Seal Type.
Valve On Casing - Clockwise Rotation
Introduction . . . . . . . . . . . . . . . . . . . . . . .
1
Special Information . . . . . . . . . . . . . . . . . . .
1
Pressure Relief Valves . . . . . . . . . . . . . . . . .
2
Maintenance . . . . . . . . . . . . . . . . . . . . . .
2
Disassembly . . . . . . . . . . . . . . . . . . . . . .
2
Installing Casing Bushing . . . . . . . . . . . . . . . .
4
Assembly . . . . . . . . . . . . . . . . . . . . . . . .
4
Pressure Adjustment . . . . . . . . . . . . . . . . . .
5
Special Pump Designs . . . . . . . . . . . . . . . . .
5
UNMOUNTED PUMP
UNITS
PACKED MECH. SEAL
Units are designated by the
unmounted pump model
numbers followed by a letter
indicating drive style.
M = Motor Mounted Unit
C56
C456
F56
F456
FH56
FH456
SPECIaL INfORMaTION
DaNgER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.)
Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor,
turbine, engine, etc.) has been “locked
out” or made non-operational so that
it cannot be started while work is
being done on pump.
3. That you know what liquid the
pump has been handling and the
precautions necessary to safely
handle the liquid. Obtain a material
safety data sheet (MSDS) for the
liquid to be sure these precautions
are understood.
failure to follow above listed
precautionary measures may result in
serious injury or death.
This manual deals exclusively with Pump Models C, F,
FH56M and C, F, FH456M General Purpose Pumps.
Refer
to figures 1, 2, 4, and 7 for general configuration and
nomenclature used in this bulletin.
All pumps can be furnished with either a mechanical seal or
packing. Packed pumps are furnished with suitable packing
for the liquid pumped. A seal pump can be changed to a
packed pump by removing the mechanical seal and inserting
the packing spring, inner packing gland, packing and outer
packing gland. The mechanical seal pump is dimensionally
interchangeable with the packed pump.
Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com
gENERaL PURPOSE hUB MOUNTED PUMPS
SERIES 56 aND 456
SIZES C - f - fh