Viking Pump TSM430: HL-N 34/434 User Manual

Technical service manual, Contents introduction, Special information

Advertising
background image

SECTION TSM 430
PAGE

1 OF 9

ISSUE

G

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

TECHNICAL SERVICE MANUAL

CONTENTS

INTRODUCTION

The illustrations used in this manual are for identification

purposes only and should not be used for ordering parts.

Secure a parts list from the factory or a Viking representative.

Always give complete name of part, part number and material

with the model and serial number of the pump when ordering

repair parts.

Introduction . . . . . . . . . . . . . . . . . . . . . . .

1

Special Information . . . . . . . . . . . . . . . . . . .

1

Safety Information. . . . . . . . . . . . . . . . . . . .

2

Maintenance . . . . . . . . . . . . . . . . . . . . . .

3

Disassembly . . . . . . . . . . . . . . . . . . . . . .

6

Assembly . . . . . . . . . . . . . . . . . . . . . . . .

7

Valve Instructions . . . . . . . . . . . . . . . . . . . .

8

UNMOUNTED PUMP

UNITS

PACKED MECH. SEAL

HL34

HL434

Units are designated by the

unmounted pump model

numbers followed by a

letter indicating drive style.

V = V-belt

KK34

KK434

LQ34

LQ434

Q34

Q434

M34

M434

N34

N434

This manual deals exclusively with series 34 and 434

Jacketed General Purpose Pumps. Refer to Figures 1

through 11 for general configuration and nomenclature used

in this manual.

FIGURE 1

ILLUSTRATION OF SERIES 34

JACKETED PUMP

FIGURE 2

CUTAWAY VIEW OF SERIES 434

JACKETED PUMP

SPECIAL INFORMATION

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or

made non-operational so that it cannot

be started while work is being done

on pump.

3. That you know what liquid the pump

has been handling and the precautions

necessary to safely handle the liquid.

Obtain a material safety data sheet

(MSDS) for the liquid to be sure these

precautions are understood.

Failure to follow above listed

precautionary measures may result in

serious injury or death.

Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com

NOTE: The Technical Service Manual for the electrically heated pumps

is located in the Universal Seal manuals: TSM 630.1 (H-LL sizes),

TSM 630.2 (LS-QS sizes) and TSM 630.3 (N-RS sizes)

JACKETED ASPHALT PUMPS

SERIES 34 AND 434

SIZES HL, KK, LQ, Q, M, N

Advertising