Viking Pump TSM320.2: GG-HL 75/475 User Manual

Technical service manual, Contents introduction, Interchangeability

Advertising
background image

SECTION TSM 320.2
PAGE

1 OF 9

ISSUE

F

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

TECHNICAL SERVICE MANUAL

CONTENTS

INTRODUCTION

The illustrations used in this manual are for identification

purposes only and

should not be used for ordering parts.

Secure a parts list from the factory or a Viking

®

representative.

Always give complete name of part, part number and

material, with the model number and serial number of the

pump when ordering repair parts. This model number and

serial number can be found on the nameplate attached to

the pump casing. This is important identification for ordering

parts or replacement pump. It is positive assurance you will

receive the correct pump parts.
Your pump is composed of four major parts. Only two of these

are moving parts: the rotor and idler.
An exploded parts drawing and list of parts is included to help

you identify each part correctly. However, to disassemble

and reassemble the pump, you will be covered step by step.

Refer to pages 2 to 9.

FIGURE 1

UNMOUNTED PUMP SHOWING

FRONT VIEW OF G AND GG SIZE

Introduction . . . . . . . . . . . . . . . . . . . . . . .

1

Interchangeability . . . . . . . . . . . . . . . . . . . .

1

Special Information . . . . . . . . . . . . . . . . . . .

1

Safety Information. . . . . . . . . . . . . . . . . . . .

2

Maintenance . . . . . . . . . . . . . . . . . . . . . .

3

Disassembly . . . . . . . . . . . . . . . . . . . . . .

4

Assembly . . . . . . . . . . . . . . . . . . . . . . . .

4

To Reassemble Model G75 & GG75 . . . . . . . . . .

4

To Reassemble Model H75, HJ75 & HL75 . . . . . . .

6

To Reassemble Model G475 & GG475 . . . . . . . . .

7

To Reassemble Model H475, HJ475 & HL475 . . . . .

8

Safety Relief Valve Instructions . . . . . . . . . . . . .

8

Pressure Adjustment . . . . . . . . . . . . . . . . . .

9

UNMOUNTED PUMP MODELS

WITH LIP SEAL

WITH MECHANICAL SEAL

G75

G475

GG75

GG475

H75

H475

HJ75

HJ475

HL75

HL475

MOUNTED PUMP MODELS

WITH

LIP SEAL

WITH

MECHANICAL

SEAL

NORMAL GPM

@ 1200

RPM

@ 1800

RPM

G75M

G475M

5

7

GG75M

GG475M

7

10

H75M

H475M

10

15

HJ75M

HJ475M

13

20

HL75M

HL475M

20

30

INTERCHANGEABILITY

These pumps are furnished with either a mechanical seal or

lip seal.
All models of the mechanical seal pumps and lip seal pumps

are dimensionally interchangeable on any NEMA “C” flange

motor. The mechanical seal is interchangeable with the lip

seal in all pump sizes.

INSTALLATION

The suction line should be air tight and at least as large as

the pump suction port connections to prevent loss of prime

or capacity. It should also be equipped with a strainer and if

pumping light liquids at a high suction lift, a foot or check valve

should be used. Always avoid high spots and obstructions in

the suction line as these may cause noise, loss of capacity

or air lock. Since these are positive displacement pumps,

be sure there is no obstruction in the discharge line and all

valves are in operating position before starting the pump. Be

sure the adjusting screws of the relief valve on the pump point

towards the suction port. Factory assembled pumps will have

right hand port suction and left hand port discharge unless

otherwise specified. Port location is determined by looking at

the mounting flange end of the pump. The relief valve on the

pump is excellent insurance against a clogged discharge line

or closed valves in the discharge line.

SPECIAL INFORMATION

ROTATION: Viking pumps operate equally well in a clockwise

or counterclockwise rotation. Shaft rotation determines which

port is suction and which is discharge. Port in area where

pumping elements (gear teeth) come out of mesh is suction

port.

Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com

GENERAL PURPOSE SPECIAL MOUNTED PUMPS

SERIES 75 AND 475

SIZES G - HL

Advertising