Technical service manual, Disassembly assembly, Pressure adjustment important – Viking Pump TSM320.2: GG-HL 75/475 User Manual

Page 9

Advertising
background image

SECTION TSM 320.2
PAGE

9 OF 9

ISSUE

F

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

DISASSEMBLY

ASSEMBLY

Follow the procedure outlined under disassembly.
If valve is removed for repairs, be sure to replace in the same

position. The valve cap should point towards the suction

port.

NOTE: Mark valve and head to be sure they are reassembled

in the same relative position.
1. Remove valve cap.
2. Measure and record the length of extension of the

adjusting screw.

See “A” on Figure 11.

3. Loosen the lock nut and back out adjusting screw until

spring pressure is released.

4. Remove bonnet, spring guide, spring and poppet from

the valve body. Clean and inspect all parts for wear or

damage and replace as necessary.

PRESSURE ADJUSTMENT

IMPORTANT

In ordering parts for the pressure relief valve, always

give model number and serial number of the pump as

it appears on the nameplate and the name of the part

wanted. When ordering springs, be sure to give the pressure

settings desired.

If the pressure setting of the safety relief valve is to be

changed from that which the factory has set, the following

instructions should be carefully followed:
1. Remove the valve cap, which covers the adjusting screw,

and loosen the lock nut that locks the adjusting screw so

the pressure setting will not change during operation of

the pump.

2. A pressure gauge somewhere in the discharge line must

be used for actual adjustment operation.

3. The adjusting screw should be turned in for increasing

the pressure or turned out for decreasing the pressure.

4. With the discharge line closed at a point beyond the

pressure gauge, the gauge will show the maximum

pressure the valve will allow while the pump is in

operation.

GENERAL PURPOSE SPECIAL MOUNTED PUMPS

SERIES 75 AND 475

SIZES G - HL