Viking Pump TSM230: Hygienic Series User Manual

Technical service manual, Contents introduction

Advertising
background image

SECTION TSM 230
PAGE

1 OF 15

ISSUE

B

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

TECHNICAL SERVICE MANUAL

FIGURE 2

JACKETED HYGIENIC SERIES

FIGURE 1

NON-JACKETED HYGIENIC SERIES

CONTENTS

INTRODUCTION

The illustrations used in this manual are for identification

purposes only and cannot be used for ordering parts. Obtain

a parts list from the factory or a Viking distributor. Always give

the complete name of part, part number and material with

the model number and serial number of pump when ordering

repair parts. The unmounted pump or pump unit model

number and serial number are on the nameplate.

In the Viking model number system, basic size letters are

combined with series number (157B, 4157B, 257B, 4257B)

indicating basic pump construction material.

This manual deals only with Series 157B, 4157B, 257B and

4257B hygienic pumps.

Refer to Figures 1 through 22 for

general configuration and nomenclature used in this manual.

Pump specifications and recommendations are listed in

Catalog Section 230, Viking Hygienic Series: Hygienic

Internal Gear Pumps.

Introduction .................................................................

1

Safety Information.......................................................

2

Special Information .....................................................

3

Maintenance ...............................................................

3

Cleaning......................................................................

4

Required Clearance for Disassembly .........................

5

Exploded View Drawing ..............................................

5

Disassembly ...............................................................

6

Assembly ....................................................................

7

Fastener Torque Values ..............................................

7

Mechanical Seal .......................................................

10

Single Seal ..........................................................

10

Double Seal .........................................................

11

Single O-ring Seal ...............................................

12

Double O-ring Seal ..............................................

12

Barrier / Buffer Fluid ............................................

13

Pump Rotation ..........................................................

13

Installation of Casing Studs ......................................

14

Disassembly & Installation of Inner Ball Bearing ......

14

Thrust Bearing Adjustment .......................................

14

Installation of Bushings .............................................

15

Warranty ...................................................................

15

Electronic copies of the most current TSM issue can be found on the Viking Pump website at vikingpump.com

UNMOUNTED PUMP

UNITS

NON-JACKETED

JACKETED

Units are designated by the

un-mounted pump model

numbers followed by a letter

indicating drive style.
V = V-Belt

D = Direct Connected

R = Viking Speed Reducer

P = Commercial Speed

Reducer or Gearmotor

ORING

SEAL

MECH

SEAL

ORING

SEAL

MECH

SEAL

H157B

HL157B

KS157B

K157B

KK157B

LQ157B

LL157B

LS157B

H4157B

HL4157B

KS4157B

K4157B

KK4157B

LQ4157B

LL4157B

LS4157B

H257B

HL257B

KS257B

K257B

KK257B

LQ257B

LL257B

LS257B

H4257B

HL4257B

KS4257B

K4257B

KK4257B

LQ4257B

LL4257B

LS4257B

VIKING HYGIENIC SERIES

HYGIENIC INTERNAL GEAR PUMPS

SERIES 157B, 4157B, 257B & 4257B

STAINLESS STEEL

SIZES H, HL, KS, K, KK, LQ, LL, LS

Advertising