Pump rotation, Warning, Cip-able port options – Viking Pump TSM230: Hygienic Series User Manual

Page 13: Additional options for cop

Advertising
background image

SECTION TSM

230

ISSUE

B

PAGE 13 OF 15

BARRIER/BUFFER FLUID

FOR DOUBLE SEAL & DOUBLE

O-RING SEAL

WARNING !

PUMPS WITH DOUBLE SEALS AND DOUBLE

O-RING SEALS REQUIRE A LIQUID BARRIER/

BUFFER FLUID. OPERATING A PUMP WITH

A DOUBLE SEAL OR DOUBLE O-RING SEAL

WITHOUT A BARRIER/BUFFER FLUID WILL

DAMAGE THE SEAL AND PUMP PARTS DUE

TO EXCESS HEAT CAUSED BY DRY RUNNING.
THE BARRIER/BUFFER FLUID FOR THE SEAL

MUST BE COMPATIBLE WITH THE PRODUCT

BEING PUMPED AND THE RELEVENT

MATERIALS OF CONSTRUCTION OF THE PUMP.
SPECIAL CONSIDERATION MUST BE GIVEN

TO THE TEMPERATURE LIMITATIONS OF THE

BARRIER/BUFFER FLUID TO ENSURE NO FIRE

OR EXPLOSION HAZARDS ARE CREATED.

1. Pumps with double seals and double O-ring seals require

a barrier/buffer fluid. The barrier/buffer fluid must be

connected and flowing whenever the pump is operated.

2. The barrier/buffer fluid must be supplied at a minimum

flow rate of 0.13 gpm (0.5 lpm).

3. For a buffer fluid, the fluid should be unpressurized
4. For a barrier fluid, the fluid pressure must be a minimum

of 15 psi (1 bar) greater than the maximum pressure

behind the rotor. Due to the casing groove, the pressure

behind the rotor is equal to the suction pressure for the

pump’s primary rotation and the discharge pressure for

the opposite rotation.

FIGURE 19

DOUBLE O-RING SEAL STATIONARY MEMBER

CAP SCREW FOR

ANTI-ROTATION

WASHER

ANTI-ROTATION WASHER

CASING

SEAL HOUSING

SEAL HOUSING O-RING

BARRIER/BUFFER FLUID CONNECTIONS

Stationary Member Installation (FIGURE 19):
1. Install the four seal housing O-rings into the seal housing.
2. Install the seal housing into the casing. When installing

the seal housing into the casing, the anti-rotation cut out

of the seal housing must line up with the anti-rotation

washer on the backside of the casing.

PUMP ROTATION

FIGURE 20

PUMP ROTATION

CIP-able Port Options

one port oriented downwards for drainability

Additional Options for COP

Idler pin (shown as ) and rotation shown

is as viewed from shaft end of pump.

Hygienic Series pumps have a primary direction of rotation

with an integral suckback groove to cool and lubricate the seal.

The port with the casing groove must be used as the suction

port for the pump’s primary rotation. Pumps may be operated

in the opposite direction for short periods of time such as for

stripping the line before cleaning. Running the pump in the

opposite direction turns the casing groove into a flush groove,

which causes the area behind the rotor and the seal to be

subjected to the discharge pressure. Pressure protection

must be provided downstream of the pump, regardless of

rotation, or damage to the pump or drive may result.
The port with a casing groove (shown as V) needs to be used

as the suction port for the pump’s primary rotation. Due to the

casing groove location, orientations C, F, J and K will require

a special casing.

A

G

B

H

C

I

D

J

E

K

F

L

5. To obtain maximum seal life, use cool, clean barrier/

buffer fluid. Use warm or hot barrier/buffer fluid if the

pumped product sets up at room temperature.

6. The barrier/buffer fluid connections are shown in

Figures 13 and 19. The NPT connection sizes for the

barrier/buffer fluid are 1/16” for H-HL and 1/8” for KS-

LS. Use the lower connection as the inlet and the higher

connection as the outlet for the barrier/buffer fluid.