9. Error messages

Error

Description

Rectification

ERROR 75

Offset entry on heating element change incorrect Repeat process

ERROR 76

Heating element faulty

Replace heating element

ERROR 110

WHP3000 housing temperature exceeded

Allow to cool down

REMOTE

Input inhibited (can only be operated using PC)

Operate using PC

LOCKED

WHA locked (lock function)

Unlock WHA

TOOL STAND

AKT30 Stand (or WBH3000 Proximity Sensor)

Connect to socket (17)

not connected

10. Accessories

For nozzle range, see p. 13
005 31 190 99

External Sensor Type K 0.5mm

005 87 367 80

Manual Control Console

005 15 048 99

Multiple stand for hot gas nozzles

005 31 191 99

Interface cable

005 33 162 99

WBH3000 Circuit Board Holder

005 33 163 99

WBH3000S Circuit Board Holder with WHA3000 Stand

005 33 386 99

WHP3000 Bottom heater

11. Items supplied

Controller with hand-piece
AKT30 Safety Stand
Nozzle Change Tool
Coded Plug
Tool Kit (2,5 mm Hex Wrench w / 2 3 mm Ø x 6 mm L screws provided)
Hot Air Nozzle
Main Power Cord 120VAC
Foot switch
Product CD-Rom (Operating Instruction incl. WHA Control Software)

Subject to technical change without notice!