Weller WHA 30 P User Manual

Page 6

Advertising
background image

Page

6

COOPER TOOLS GmbH
Carl-Benz-Str. 2 74354 Besigheim 3
Germany Tel: 07143-580-0, Fax: 07143-580-108
www.cooperhandtools.com/europe

2. Placing in operation

Place the hand-piece, with the hot air nozzle installed, in the AKT30 safety stand. (The device
cannot be placed in operation without the safety stand or optional WBH3000S Circuit Board Holder.)
Plug cable from safety stand or optional WBH3000S Circuit Board Holder (proximity switch), into
socket (17). Check whether the mains voltage matches the information on the rating plate. If the
mains voltage is correct, connect the controller to the mains. When the device is switched on, the
device name "WHA3000" and the software "Version" are displayed briefly. The electronics then
switch automatically to the default setting (Manual operating mode).

2.1 Manual operating mode

Information on display (1)

Nozzle

Air

Nozzle

Temp.

Flow Rate

Pre-Heating

in °C/°F

in l/min

ON/OFF

In the Manual operating mode the parameters for the nozzle temperature, air flow rate and switching
on or off the pre-heating can be set.

Select the parameter by pressing the Control Key:

TEMP (7):

Nozzle temperature in °C/°F
(see Switching Temperature Conversion page 11)

AIR (6):

Air flow rate in l/min

TIME/
PREHEAT
(5):

Switch ON - OFF the nozzle pre-heating (standby) at 200°C/392°F with 5 l/min
airflow

After selection, the setting can be changed using the UP (2) or DOWN (3) Control Keys. Keeping the
Control Key depressed, rapidly changes the value.

The hot air and the nozzle vacuum are activated:
Directly on the Control Panel:

Hot air START/STOP Control Key (10), Vacuum VAC Control
Key (11)

or using the optional accessories:
2-Position Foot Switch (20):

Hot air-Position 1, Vacuum-Position 2
(hot air and vacuum are only active in the Manual Mode, when
the Foot Switch is depressed)

Manual control console (20):

Hot Air "AIR Control Key, Vacuum "VAC Control Key

When the hand-piece is placed in the AKT30 Safety Stand (17), the hot air is switched off by a Mirco
Switch. If the nozzle pre-heating is active (PREHEAT ON), the device switches to the standby mode
with reduced temperature and air flow rate (200°C / 392°F 5l/min).

TEMP

AIR

PREHEAT

350°C

25 l

OFF

Advertising