2.2 Automatic operating mode
The Automatic operating mode has a 3-step temperature-time profile.
The temperature-time profile can be expanded by connecting an optional WHP3000 bottom heater.
When the WHP3000 is connected via the RS232 interface (22) the bottom heater is integrated into
the time profile.

The temperature profile is comprised of the following 3-steps:
Pre-heat phase, system

Step 1

(ends with an audible tone)

Pre-heat phase, component Step 2
Reflow process (soldering) Step 3

The soldering process is normally started with the hot gas nozzle raised. At the end of step 1 there
is an audible tone, after this tone the nozzle should be placed over the component in the soldering
position. At the end of Step 3, raise or remove the nozzle from the application.

The following pre-settings must be made on the WHA3000P controller to define a customer-specific
temperature-time profile.

Settings step 1 step 3
Nozzle temperature

50°C 550°C (150°F / 999°F)

Temperature, bottom heat

50°C 400°C (150°F / 750°F) (optional with WHP3000)

Air flow rate

5 l/min 50 l/min

Time for the program step 0 sec. 999 sec.

The Automatic operating mode can be selected by pressing the AUTO/MAN Control Key.
The light emitting diodes (LED s) (13) indicate the related operating state.

Information on the display (1)

Nozzle or
bottom heater symbol

Temperature of the nozzle or
bottom heater (with WHP3000)

Air flow rate in l/min

Time remaining for the
temperature profile step in sec.

TEMP

AIR

TIME

210°C

40 l

100s

300°C

25 l

50s

210°C

30 l

15s

step 1
step 2
step 3

Nozzle
Pre-Heater
Nozzle

Advertising