3. A

SSEMBLY

W

HEATHEART

- H

YDROSTATIC

B

IN

S

WEEP

3.2. H

YDRAULIC

P

UMP

K

IT

I

NSTALLATION

(P

ORTABLE

M

ODEL

)

S

TANDARD

, P

ORTABLE

, T

RUCK

M

OUNT

, & S

UPER

S

WEEP

14

IM1 R3

2. Cut 3" off the center rod so that the end of the auger bearing to the center of

the pivot hole measures about 9”. Set the auger at the usual height for

loading trucks. Weld in the pivot bracket, level to the floor. The center of the

motor shaft should be about 3”-4” off the floor. Be careful that the pivot hook

does not touch the auger flighting when inserted. Refer to Figure 3.2.

Figure 3.2 Mounting Spider on Center Top Cages

Note:

The end of the auger bearing to the center of the pivot hole should measure
approximately 9”.

3.2. HYDRAULIC PUMP KIT INSTALLATION (PORTABLE

MODEL)

1. Place the single groove pulley (supplied) behind the grain auger drive pulley

on the gas/electric engine. In most cases, the pump bracket bolts directly to

the gas engine (see Figure 3.3). If using an electric motor or if otherwise

necessary, L brackets can be supplied to bolt the pump to the grain auger

motor mount.

Important:

Pump placement may be changed, but the pump must run in a counterclockwise
direction (when facing the pump) within working speeds of 3000-3500 rpm.

Figure 3.3