Great Plains V-300F Operator Manual User Manual
Page 62

V-300, V-300F
148-057M
6/29/2006
60
Selecting the Tramline Sequence
1.
Select the
channel.
2.
Hold
to enter program mode 1.
After 3 seconds the first two digits flash, indicating the tramline
sequence currently set:-
‘SY’=Symmetric
‘AL’=Asymmetric Left
‘Ar’=Asymmetric Right
‘AS’=Special Asymmetric sequences e.g. 10 bout and 18
bout.
3.
Continue holding the
button and press and HOLD
the
button to select the required sequence.
Setting the Tramline Bout
4.
PRESS and RELEASE the
button to toggle between
the tramline sequence and tramline bout number display.
The 3
rd
and 4
th
digits flash indicating the tramline bout number
currently set.
5.
PRESS and HOLD the
button to cycle tramline the
bout from 1 to 15.
NOTE: If either asymmetric left (‘AL’) or asymmetric right (‘Ar’) se-
quences are selected, the tramline output is also switched on for
the bout following the target bout (i.e. bout 1).
If the special asymmetric sequence (‘AS’) is selected, the only op-
tions for the tramline bout number are 10 and 18.
2
4
5
2