Opener frame down-force – Great Plains 2S-2600HDF Operator Manual v2 User Manual

Page 66

Advertising
background image

62

2S-2600HD

Table of Contents

Index

Great Plains Manufacturing, Inc.

195-069M

Table of Contents

Index

2014-02-03

Opener Frame Down-Force

Crushing Hazard: You will be seriously injured or killed if you
are caught between raising openers and drill frame. Always
stop tractor engine, set park bake, and remove key before
adjusting or servicing openers. Keep all bystanders well away
during drill operation.

High Pressure Fluid Hazard: Escaping fluid under pressure
can penetrate the skin causing serious injury. Avoid the hazard
by relieving pressure before disconnecting hydraulic lines. Use
a piece of paper or cardboard, NOT BODY PARTS, to check
for suspected leaks. Wear protective gloves and safety glasses
or goggles when working with hydraulic systems. If an acci-
dent occurs, seek immediate medical attention from a physi-
cian familiar with this type of injury.

Hydraulic opener down pressure controls drill-wide
opener penetration and press-wheel soil firming. Use
only enough down pressure to cut a furrow and maintain
proper soil-firming over seed. Excessive opener down
force may cause bulldozing of the openers in light soil
conditions, and leads to premature wear on opener com-
ponents.

The table at right shows the approximate force at open-
ers for a given pressure at the pressure control valve.

Note: To account for additional compaction from drill and

tractor tires, and Point Row option is not installed,
set pressure on inboard (“CENTER”) openers
slightly higher than outboard (“WING”) openers.

To run the drill with constant opener down pressure
requires an Active Hydraulic System. An Active Hydraulic
System requires a tractor with closed-center hydraulics
or pressure/flow compensated hydraulics powered by a
variable displacement hydraulic pump. (If you are not
familiar with your tractor’s hydraulics, consult your tractor
dealer.)

Equipment Damage Risk: Tractors with load-sensing hydrau-
lics must use the bypass valve to operate the 2S-2600HD. Fail-
ure to use the bypass valve can cause major tractor damage.
Before adjusting opener down pressure, set bypass valve per
Setting the Bypass Valve” on page 19.

Note: To run the drill on tractors with open-center hydrau-

lics or on tractors with fixed displacement hydraulic
pumps you must install a Great Plains kit, part num-
ber 194-143A. Contact your Great Plains dealer for
ordering information. See “Non-Active Hydraulic
System
” on page 34.

Pounds of Force at Opener Disks

Gauge

Setting

Row Spacing

6in

7.5in

10in

200 PSI

130

135

144

300 PSI

136

144

155

400 PSI

143

152

167

500 PSI

148

160

179

600 PSI

154

167

189

700 PSI

157

172

196

800 PSI

161

178

205

900 PSI

166

184

213

1000 PSI

171

190

223

1100 PSI

172

194

228

1200 PSI

180

203

240

1300 PSI

184

208

248

1400 PSI

189

215

258

1500 PSI

193

220

264

1600 PSI

198

227

274

1700 PSI

202

a

a. An empty standard drill (no markers, no fertilizer

capability and no small seeds capability) may
have insufficient available weight to reach these
force levels.

232

281

1800 PSI

209a

240

291

1900 PSI

213a

247

300

2000 PSI

217a

253a

309

2100 PSI

222

b

b. These down forces may be beyond the capability

of a drill with markers.

260a

318

2200 PSI

227

b

266a

327a

2300 PSI

232

b

273

b

336a

Advertising