Proximity sensor adjustment, Gang cylinder purging, Proximity sensor adjustment gang cylinder purging – Great Plains 3000TM Assembly Manual User Manual

Page 35

Advertising
background image

Great Plains Manufacturing, Inc.

Assembly

31

11/12/2013

586-536Q-ENG

Proximity Sensor Adjustment

Refer to Figure 26
Note: Wings need to be folded up when adjusting the

proximity sensor

to prevent damage to sensor

and bracket. Be sure and adjust proximity sensors
before unfolding. Be sure wing safety lock pins are
installed

117.Loosen nuts

(one on front and one on back side of

sensor bracket, adjust the proximity sensor

to 1/8”

to 1/4”, from front of proximity sensor

to rear of

wing tube

as shown.

118.Re-tighten nuts

to secure proximity sensor

.

Gang Cylinder Purging

Refer to Figure 27

Note: Refer to hydraulic layouts in “Appendix” section of this

manual for proper gang hose routing on center and
wings. See “Hydraulic Connector ID” on page 40 for
proper fitting installation. See “Hose Clamp Assembly
on page 17
for proper clamping of hoses.

119.Retract and extend the gang system

(Red Handles)

several times to purge air from system. Watch for leaks
and retighten fittings if necessary.

1

2

1

3

4

2

1

Figure 26

Priority Sensor Adjustment

43015

2

4

3

1

2

1

U

D

F

B

L

R

Figure 27

Gang Cylinder Purging

42978

1

1

Advertising