Great Plains 606NT Material Rate User Manual

Page 21

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Main Box Rates

Small Seeds Rate

19

2011-10-21

Table of Contents

Main Box Rates

151-122B

12. Turn crank at a steady rate until one tenth acre is

tallied on acremeter. While turning, check that cups
have ample seed coming into them.

13. Weigh metered material. Subtract initial weight of

container(s).

14. Divide the net material weight by three. Multiply by

number of openers on your drill, and then by ten, to
determine the total of pounds per acre applied.

15. Divide the desired original field rate by the measured

rate to calculate a scale adjustment factor.

16. Multiply the scale setting just used times correction

factor to obtain the next scale setting to use.

17. Set the Small Seeds Rate Handle to the new scale

setting.

18. You may want to repeat calibration procedure at the

new setting if your results varied greatly from the
Seed Rate Chart, or if you must operate near the
ends of the Seed Rate handle scale (0-20 or
90-100).

19. Check that your tire(s) is (are) properly inflated. See

Tire Inflation Chart” in Operator manual.

20. With calibration complete, store calibration crank,

re-engage hub if locked-out, reinstall any removed
chains or sprockets, reconnect seed hoses and re-
install acremeter (if removed - tighten only to snug).

When drilling, check seeding rate by noting acres drilled,
amount of seed added to drill and seed level in drill box.
If you are seeding more or less than desired, adjust rate
slightly to compensate for field conditions.

Drill Model

Rotations Per Acre (ha)

3P606NT

or 3P605NT

Crank: 913 (2256) rotations

3P606NT

or 3P605NT

Tire: 1628 (4015) rotations

606NT or 605NT

Any: 995 (2459) rotations

3P606NTcrank rotations for one tenth acre is:

91.3

Example:
the three containers weighed a total of
1.13 pounds after test: 0.43 lbs net

0.43

1.13

0.70

=

NetWeight

GrossWeight

ContainerWeights

=

Example: 10.0 lbs/ac

12.8

0.43

3

----------- 9

Ч

10

Ч

=

MeasuredRate

NetWeight

3

--------------------------- RowCount

Ч

10

Ч

=

Example: the target rate was 12 lbs/ac:
the correction factor =1.2

0.94

˙

12

12.8

-----------

=

CorrectionFactor

FieldRate

MeasuredRate

--------------------------------------

=

Example: the previous scale setting was 60,
the next scale setting is 56

56

60

0.94

×

=

NextScale

PreviousScale

CorrectionFactor

Ч

=

Advertising