Main box seed rate calibration – Great Plains 606NT Material Rate User Manual

Page 7

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Main Box Rates

Main Box Seed Rate

5

2011-10-21

Table of Contents

Main Box Rates

151-122B

Main Box Seed Rate Calibration

Differences will exist between the tested seed and field
conditions used to generate the Seed Rate Charts, and
your seed and conditions. To accurately achieve your
target population, Great Plains recommends calibrating.

Due to the large number of crank revolutions per acre
(913 or 995) and per hectare (2256 or 2458), a practical
calibration is a simulation of

1

10

th

acre or

1

10

th

hectare.

1.

Estimate the sample sizes.

2.

To perform this calibration, you need a scale that is
accurate at the aggregate sample size, and three (3)
light containers, each capable of holding the
expected SamplePerRow. Record the empty
container weights.

3.

For a 3P605NT or 3P606NT drill, raise the drill so
the gauge wheel is out of ground contact.

For a 605NT or 606NT drill, disengage the lock-out
hub (see Operator manual), to permit independent
rotation of the main jackshaft. The drill may be raised
or lowered for calibration. Leave the lock-out hub
engaged if rotating the tire for calibration.

Crushing Hazard:
Install lift locks on a raised 605NT or 606NT drill.

4.

Remove the calibration crank from its storage stob.
Store the retaining pin on the stob.

Refer to Figure 7 or Figure 8
5.

Place the hex socket of the crank on the left end of
the main jackshaft.

Note: On the 605NT or 606NT you can also rotate the

gearbox input jackshaft by means of a wrench or
socket. You may need to remove the acremeter.
Use same number of rotations when turning the
gauge wheel jackshaft, gearbox input jackshaft or
tire.

Note: On the 3P605NT or 3P606NT you can also rotate

the gearbox drive shaft with wrench or socket.

6.

Pull the seed hoses off the top of three opener seed
tubes, at the top of the openers. Place the hoses into
each sample container.

Figure 7

3P606NT Calibration Crank

32793

Example: You want to apply barley at 60 pounds per
acre with a 3P606NT drill. RateSample is:

Example: the drill has 9 rows. SamplePerRow is:

Example: 3 rows are to be used in the sampling.
ExpectedSample is:

The expected sample weight is 2.0 lb.

Example: 3 containers, each weighing 0.5lb:

ContainerWeight = 1.5 lb

6.0

60
10

------

=

0.67

6.0

9

--------

=

2.0

0.67

3

×

=

RateSample

FieldRate

10

----------------------------

=

SamplePerRow

RateSample

RowCount

-----------------------------------

=

ExpectedSample

SamplePerRow

SampledRows

×

=

Figure 8

606NT Calibration Crank

23389

Advertising