Mount left inner-most yp1225/1625 smartbox, Mount right inner-most yp1225/1625 smartbox – Great Plains Smartbox Mount Kit Yield Pro Planters User Manual

Page 11

Advertising
background image

Great Plains Mfg., Inc.

Installation Instructions

11

12/12/2006

403-206M

Mount Left Inner-Most YP1225/1625 Smartbox

Refer to Figure 17 and Figure 20

25. Select:

one

Smartbox frame,

two (18) 403-319D,
(SMART BOX HOLD DOWN CLAMP),
two (27) 802-223C,
(HHCS 3/8-16X4 GR5),
two (26) 802-079C,
(HHCS 3/8-16X1 1/4 GR5), and
four (31) 803-209C,
(NUT FLANGE LOCK 3/8-16 PLT).

If the base container is already installed on the
SmartBox frame, it may be necessary to remove it
to gain access to the mounting holes.

26. Insert a 1

1

4

in bolt (26) in the forward slotted

mounting hole

on one side of the frame

. Slip

the shorter end of a clamp (18) over the bolt (26)
and add a flange lock nut (31). Put only a few turns
on the nut.

27. Position the frame

about 4in from the end of the

inner-most end of the new tube

, or directly next

to the air pipe support plate.

28. Insert a 4in bolt (27) in the slotted hole

just for-

ward of center on each side of the frame

, and

then down through the hole in the clamp (18), and
add a flange lock nut (31). Put only a few turns on
the nut.

29. Alternately tighten the lock nuts (31), keeping the

Smartbox frame

and the base of the clamp (18)

parallel to the tube

top and bottom, and the front

of the clamp snug against the front of the tube.

30. Repeat Step 26 through Step 29 for the other side

of the frame

.

31. Position Smartbox base container/meter or

container/splitter/meter assembly

in the frame

, having the meter ports biased to the Right, and

secure with fasteners provided by AMVAC.

Mount Right Inner-Most YP1225/1625 Smartbox

32. Repeat Step 25 through Step 31 for the innermost

Smartbox on the right side of the machine, using a
Smartbox base container/meter or container/
splitter/meter assembly with the meter exit port(s)
biased to the Left.

Figure 17

Near-Pivot Mounting

25329

18

27

31

26

U

D

B

F

R

L

18

Figure 18

YP1225/1625 Inner-Most

24176

26

31

18

31

26

Advertising